The CR3000 Micrologger® supports complex applications with many sensors. It is fast and powerful enough to handle extended eddy-covariance systems with full energy-balance systems. Multiple CR3000s can be configured as a network or units can be deployed individually.
Designed for stand-alone operation in harsh, remote environments. The CR3000 consists of a compact, integrated package with a built-in power supply, a 128-by-64-pixel backlit graphical or eight-line numeric display, and a 16-character keyboard.
Benefits and Features
- Ideal applications include eddy covariance, wind profiling, HVAC, weather stations, vehicle testing, air quality, process control, mesonet systems, agriculture, soil moisture, time-domain reflectometry, water quality
- Integrated keyboard and display screen let you program, manually initiate data transfers, and view data, all on site.
- Includes a current excitation channel allowing direct connection of PRTs or other sensors that use a current excitation
- Serial communications with serial sensors and devices supported via I/O port pairs
- Supports PakBus, Modbus, SDI-12, and DNP3 protocols
- Communicates via various options: TCP/IP, email, FTP, web server.
- Gas Discharge Tube (GDT) protected inputs
- 4-MB memory can be expanded with add-on memory systems.
- Flexible power and communication options make it ideal for remote locations.
- Compatible with channel expansion peripherals allowing you to expand your system
- Battery-backed SRAM and clock that ensure data, programs, and accurate time are maintained while datalogger is disconnected from the main power source
- Contains custom ASIC chip that expands pulse count, control port, and serial communications capabilities
- Program with LoggerNet, PC400, or ShortCut to fit your setup.
- Collects and stores data and controls peripherals as the brain of your system
CR3000 Specifications
- Maximum Scan Rate: 100 Hz
- Analog Inputs: 28 single-ended or
14 differential, individually configured
- Pulse Counters: 4
- Switched Excitation Channels: 4 voltage,
3 current
- Digital Ports1: 3 SDM and 8 I/Os or
4 RS-232 COM2
- Continuous Analog Outputs: 2
- Communications/Data Storage Ports:
1 CS I/O, 1 RS-232, 1 parallel peripheral
- Switched 12 Volt: 2
- Input Voltage Range: ±5 Vdc
- Analog Voltage Accuracy:
±(0.04% of reading + offset), 0° to 40°C
- Analog Resolution: 0.33 µV
- A/D Bits: 16
- Power Requirements: 10 to 16 Vdc
- Protocols Supported: PakBus, Modbus, DNP3, FTP, HTTP, XML POP3, SMTP, Telnet, NTCIP, NTP, SDI-12, SDM
- CE Compliance Standards to which Conformity is Declared: IEC61326:2002
- Warranty: 3 years
Temperature Range3
- Standard: -25° to +50°C
- Extended: -40° to +85°C
Memory
- Operating System: 2 MB Flash
- CPU Usage, Program Storage, and Data Storage: 4 MB
Typical Current Drain @ 12 Vdc
- Sleep Mode: < 2 mA
- Active (w/o RS-232 communication): 3 to 30 mA typical
- Active (w/RS-232 communication): 17 to 47 mA typical
Dimensions
- With Low-Profile Base:
24.1 x 17.8 x 7.6 cm
(9.5" x 7.0" x 3.0")
- With Alkaline Battery Base:
24.1 x 17.8 x 11.9 cm
(9.5" x 7.0" x 4.7")
- With Rechargeable Battery Base:
24.1 x 17.8 x 11.9 cm
(9.5" x 7.0" x 4.7")
Weight
- With Low-Profile Base: 1.6 kg (3.6 lb)
- With Alkaline Battery Base:
3.8 kg (8.3 lb)
- With Rechargeable Battery Base:
4.8 kg (10.7 lb)
1Certain digital ports can be used to count switch closures.
2I/O ports can be paired as transmit and receive for measuring smart serial sensors.